Produkt finden

E:Garantia del fabbricante e garantia

18 months guarantee

18 months guarantee for all components not subject to specific wearing

6 - 18 months additional warranty

Additional wearing-independent warranty terms on sensors, thermocouples, batteries with 6 – 18 months running time

10 YEARS ecom WARRANTY

10 YEARS ecom WARRANTY on:
– Aluminium housing
– Free instrument firmware update (made along with instrument check, maintenance or repair)
– Re-supply of spare parts

Preparazione gas

Condensate trap, optical monitoring
Condensate trap, electronic monitoring
Gas cooler

Gas cooler with electronic condensate monitoring
(by NOx/SOx measurement due to increased water-solubility => “dry cooling” of sampled gas)

Automatic condensate evacuation

Sistema di campionamento gas

Sampling probe (standard)

Probe for gas sampling (standard)

Sampling probe (heated)

Probe for gas sampling, heated (for integral soot measurement)

Heated sampling system

Heated sampling system (e.g. for labor measurements)

Trasporto gas

Multi-chamber silicone tubing
NOx/SOx special tubing

NOx/SOx special tubing with PTFE inner coating
(by NOx/SOx measurement)
NOx/SOx special tubing with PTFE inner coating
(by NOx/SOx measurement)
NOx/SOx special tubing with PTFE inner coating
(by NOx/SOx measurement)
(NOx/SOx special tubing with PTFE inner coating
(by NOx/SOx measurement)

Heated tubing

Heated tubing (in connection with heated gas sampling system)

Monitoraggio remoto

Bluetooth remote monitor

Bluetooth remote monitor (ecom-R)
– not possible in connection with WiFi option, Bluetooth remote monitor (ecom-R)

Smartphone remote monitoring

Remote monitoring via smartphone (iOS resp. Android App) via WiFi
– not possible in connection with Bluetooth option, remote monitoring via smartphone (iOS resp. Android App)

Remote monitoring by radio

Wireless radio monitoring (highest coverage)

Connettività

Via connection cable

PC software (free of charge) – data transfer via connection cable

Via SD card

PC software (free of charge) – data transfer via SD card

Via Bluetooth

PC software (free of charge) – data transfer via Bluetooth (not possible in conection with WiFi option)

Via WiFi

Smartphone connection – data transfer via WiFi (not possible in connection with Bluetooth option) – ecom Remote Monitor App (iOS + Android) free of charge

Stampante

Integral printer
External printer

Ulteriori parametri di misura

T-Air - 0…99°C
Pressure /∆P (chimney draught) - ± 100 hPa
Temperature trend indication for core stream search - °C
Indication of pump performance (l/min)

Valori calcolati

CO2 .- 0…CO2 max
Combustion efficiency (ETA) - 0…120%
Excess air (Lambda) - > 1
Gas losses qA - 0…100%
CO(U) undiluted - x ppm
Dew point - x °C
mg/m3 - x mg/m3
mg/KWh - x mg/kWh
O2-rest - x % O2

Componenti gas

O2 (0…21 vol %) - electrochemical
CO (by H2-compensation 0-10.000 ppm) - electrochemical
CO% (0-63000 ppm)
NO (0-5000 ppm) - electrochemical
NOLow (0-500 ppm) - electrochemical
NO (0-1000 ppm) - CLD measurement
NO2 (0-1000 ppm) - electrochemical
NO2Low (0-100 ppm) - electrochemical
NO2 (0-200 ppm) - PAS measurement
NOx - CLD + converter

Conversion of NO2 into NO and measurement of up to 1.000 ppm by conversion in NOx value; no original NO2/NOx measurement possible with CLD.

SO2 (0-5000 ppm) - electrochemical
SO2 (0-1000 ppm) - IR bench
H2 (0 up to 20000 ppm) - electrochemical
H2S (0-1000 ppm) - electrochemical
HCl (on request) - electrochemical
NH3 (on request) - electrochemical
CxHy (0…4 vol. %) - catalytic
CO2 (0-20000 ppm) - IR sensor
CH4 (0 up to 30000 ppm) - IR sensor
CO (0-1000 ppm) - IR bench

0-2000 ppm also alternatively possible.

CO% (0-63000 ppm) - IR bench
CO2 (0-20 vol-%) - IR bench
CxHy (CH4 - 0- 30000 ppm) - IR bench
CxHy (C3H8 - 0-20000ppm) - IR bench

Temperatura gas

0…500 °C
0…1.000 °C
> 1.000 °C

Tipo di strumento

Handheld instrument
Compact instrument in transport case

Misura industriale

Metal processing (i . a. steel)
Aluminium processing
Cement production
Coke oven gas
Petrochemicals
Others
For checks / adjustments
For series measurements

Misura a motori

For checks / adjustments
For series measurements

Misura ad impianti di combustione larghi

For checks / adjustments
For series measurements
Integral soot measurement acc. to soot comparison scale (no soot pump required)

Accessori

Simultaneous temperature measurement
TRGI accessories

TRGI accessories (tubings, quick-fittings, various test stopples, one-pipe counter cap, connection piece with safety valve…)

Adjustment accessories "Gas Burner"
Tubing set - for operation pressure up to 1 bar
Tubing set - for operation pressure up to 10 bar
Thermal quick-printer
Measurement data recording

Measurement data recording (memorization + data logging)

Transport case resp. pouch

Misure ad impianti di riscaldamento

At all heating plants types

Measurements at gas heatings and oil-fired plants (with soot pump) as well as those fired by solid fuel types

With integral soot measurement

For all heating plants – incl. integral soot measurement, especially comfortable for oil-fired plants (no soot pump required)

Applicazione

Adjustment of gas burners

Nozzle pressure check
Measurement of device connection pressure

Tightness check of gas fittings (± 100 to 150 hPa)
Check of gas pipeworks

– Tightness checks acc. to TRGI (150 hPa)
– Stress test acc. to TRGI (1 bar)
– Leakage rate measurement in the course of suitability test  acc. to TRGI – Tightness checks acc. to TRGI (150 hPa)
– Stress test acc. to TRGI (1 bar)
– Leakage rate measurement in the course of suitability test acc. to TRGI

Check of liquid gas pipeworks

– Tightness check acc. to TRF (150 hPa)
–  Stability test acc. to TRF (1 bar) – Tightness check acc. to TRF (150 hPa)
–  Stability test acc. to TRF (1 bar)

Check of water pipeworks

– Tightness check of pressed connections (6 bar)
– Tightness check acc. to DIN EN 806-4  – Drinking water resp. air pressure – (11 bar)

Tightness check of heating plants

– Tightness check acc. to DIN 18380 (2.5 or 3 bar; acc. to set pressure of safety valve)

Check of sewage plants

– acc. to DIN 1610

Adjustment of gas engines

– Gas pressure check (±80 hPa to 8 bar)
– Differential pressure at intercooler (±20 to 700 hPa)
– Exhaust gas pressure (±5 to 120 hPa)
– Differential pressure at BlowBy filter (5 to 50 hPa)
– Crank case pressure (-5 to 100 hPa)

MISURE A MOTORI, CENTRALI TERMICHE, IMPIANTI BIOMASS o simile (cogenerazione)

Tecnica di filtrazione

Probe pre-filter

Probe pre-filter made out of sinter metal

Filtering plate

Filtering plate (for solid fuel types measurement)
Positioning at aluminium-framed transport case

Filtering case

Filtering case (for solid fuel types measurements)

Gas washing bottle

Gas washing bottle (elimination of solid particles in sampled gas)
– not suitable by NO2/SO2 measurement due to water-solubility
of these particles
– gas cooler required (for subsequent gas drying)

Attrezzatura / Accessori

Soot pump set
Multi-hole probe (O2 content)

Ring slot multi-hole probe (for measurement of oxygen content in the combustion air of room-independent combustion plants)

Multi-hole probe (CO concentration)

Universal CO multi-hole probe (for measurement of CO concentration within the frame of safety-related checks of gas-fired plants)

Tubing for differential pressure measurement

Tubing for differential pressure measurement up to 100 hPa

Set for TRGI measurements
T-Room stick

T-Room stick for determination of ambient temperature at analyser

T-Room probe

T-Room probe, tip length 260 mm  – i.a. determination of sucking temperature by concentric exhaust plants

Contact sensor

Contact sensor – for differential temperature mesurement of water (when entering and leaving the heating system)

Dynamic pressure probe

Dynamic pressure measurement in exhaust gas – option with dynamic pressure probe

8-channel analog output box

8-channel analog output box (for external data evaluation in V/mA)

Instrument internal heating

Instrument internal heating

Approvazioni

according to EN 50379-2

according to EN 50379-2 (fulfills the requirements by law-regulated measurements and assessments)

acc. to 1st BimSchV

Singolarità dei prodotti

EXTREMELY accurate.

EXTREMELY accurate.
3-point climatic chamber calibration for sensors´ temperature compensation for EXACT measurement results

EXTREMELY efficient.

EXTREMELY efficient.
Up to 5-time higher pump performance (2.6 l/min)

EXTREMELY safe.

EXTREMELY safe.
– automatic CO switch-off by concentration overexposure
– no measurement interruption (CO sensor purge with fresh air)

EXTREMELY robust.

EXTREMELY robust.
– thanks to ultralight but resistant aluminium housing
– thanks to aluminium-framed transport case (when applicable)

EXTREMELY broad reach.

EXTREMELY broad reach.
– thanks to data transfer via WiFi/Bluetooth
– thanks to remote monitor/command features

EXTREMELY cool.

EXTREMELY cool.
– constant drying by 5°C via gas cooler
– perfect gas preparation by NOx/SOx measurement

EXTREMELY loss-free.

EXTREMELY loss-free.
Quick, effective gas transport i. a. for accurate NO2/SO2 measurement provided by sampling tubing with PTFE sleeve with restricted diameter

EXTREMELY complete.

EXTREMELY complete.
ecom products are always designed and quoted with the complete equipment needed for a ready-to-measure operation and they furthermore come with: additional consumables (e.g. spare printer paper roll/filter) and free downloadable PC software

Campi di misura

0-10 hPa

Resolution: 0.1 Pa, accuracy: ±0.3 Pa or 3 % of measurement value

0-70 hPa

Resolution: 0.01 hPa, accuracy: < 3% of measurement value

0-100 hPa

Resolution: 0.01 hPa, accuracy: ±0.5 hPa or 1% of measurement value

0-200 hPa

Resolution: 0.01 hPa, accuracy: 1% of measurement range end value

0-1500 hPa

Resolution: 0.1 hPa, accuracy: < 3% of measurement value (according to  pressure sensor type installed: higher)

0-1 bar

Resolution: 0.1 hPa, accuracy: 0.3% of measurement end value

0-10 bar

Resolution: 0.001 bar, accuracy: 0.5% of measurement end value

0-20 bar

Resolution: 0.01 bar, accuracy: 0.5% of measurement end value

0-40 bar

Resolution: 0.01 bar, accuracy: 0,5% of measurement end value

Two Parallel Measurements Possible

Specifications not configurable? Just send us an enquiry – we will find a solution.